World Library  
Flag as Inappropriate
Email this Article

Thermosiphon

 

Thermosiphon

Thermosyphon circulation in a simple solar water heater

Thermosiphon (alt. thermosyphon) is a physical effect and refers to a method of passive heat exchange based on natural convection, which circulates a fluid without the necessity of a mechanical pump. Thermosiphoning is used for circulation of liquids and volatile gases in heating and cooling applications, such as heat pumps, water heaters, boilers and furnaces. Thermosiphoning also occurs across air temperature gradients such as those utilized in a wood fire chimney, or solar chimney.

This circulation can either be open-loop, as when the substance in a holding tank is passed in one direction via a heated transfer tube mounted at the bottom of the tank to a distribution point—even one mounted above the originating tank—or it can be a vertical closed-loop circuit with return to the original container. Its purpose is to simplify the transfer of liquid or gas while avoiding the cost and complexity of a conventional pump.

Contents

  • Simple thermosiphon 1
    • Heat pipes 1.1
    • Reboilers and calandria 1.2
  • Solar energy 2
  • Computing 3
    • Uses 3.1
    • Drawbacks 3.2
  • Engine cooling 4
  • See also 5
  • References 6
  • External links 7

Simple thermosiphon

Convective movement of the liquid starts when liquid in the loop is heated, causing it to expand and become less dense, and thus more buoyant than the cooler liquid in the bottom of the loop. Convection moves the heated liquid upwards in the system as it is simultaneously replaced by cooler liquid returning by gravity. Ideally, the liquid flows easily because a good thermosiphon should have very little hydraulic resistance.

Heat pipes

In some situations the flow of liquid may be reduced further, or stopped, perhaps because the loop is not entirely full of liquid. In this case, the system no longer convects, so it is not a usual "thermosiphon".

Heat can still be transferred in this system by the evaporation and condensation of vapor; however, the system is properly classified as a heat pipe thermosyphon.[1][2] If the system also contains other fluids, such as air, then the heat flux density will be less than in a real heat pipe, which only contains a single fluid.

The thermosiphon has been sometimes incorrectly described as a 'gravity return heat pipe'.[3] Heat pipes usually have a wick to return the condensate to the evaporator via capillary action. A wick is not needed in a thermosiphon because gravity moves the liquid.[4] The wick allows heat pipes to transfer heat when there is no gravity, which is useful in space. A thermosiphon is "simpler" than a heat pipe.[5]

(Single-phase) thermosiphons can only transfer heat "upward", or away from the acceleration vector. Thus, orientation is much more important for thermosiphons than for heatpipes. Also, thermosiphons can fail because of a bubble in the loop, and require a circulating loop of pipes.

Reboilers and calandria

If the piping of a thermosiphon resists flow, or excessive heat is applied, the liquid may boil. Since the gas is more buoyant than the liquid, the convective pressure is greater. This is a well known invention called a reboiler. A group of reboilers attached to a pair of plena is called a calandria.

The term "phase change thermosiphon" is a misnomer and should be avoided. When phase change occurs in a thermosiphon, it means that the system either does not have enough fluid, or it is too small to transfer all of the heat by convection alone. To improve the performance, either more fluid is needed (possibly in a larger thermosiphon), or all other fluids (including air) should be pumped out of the loop.

Solar energy

Solar heating system featuring a thermosiphon

Thermosiphons are used in some liquid-based solar heating systems to heat a liquid such as water. The water is heated passively by solar energy and relies on heat energy being transferred from the sun to a solar collector. The heat from the collector can be transferred to water in two ways: directly where water circulates through the collector, or indirectly where an anti-freeze solution carries the heat from the collector and transfers it to water in the tank via a heat exchanger. Convection allows for the movement of the heated liquid out of the solar collector to be replaced by colder liquid which is in turn heated. Due to this principle, it is necessary for the water to be stored in a tank above the collector[6]

Computing

Thermosiphons are used in computing[7] to describe a system for watercooling the internal computer components, most commonly referring to the processor. While any suitable liquid can be used, water is the easiest liquid to use in thermosiphon systems. Unlike traditional watercooling systems, thermosiphon systems do not rely on a water pump (or a pump for other liquids) but rely on convection for the movement of heated water (which may become vapour) from the components upwards to a heat exchanger. There the water is cooled and is ready to be recirculated. The most commonly used heat exchanger is a radiator where air is blown actively through a fan system to condense the vapour to a liquid. The liquid is recirculated through the system, thus repeating the process. No pump is required—the vaporization and condensation cycle is self-sustaining.

Uses

Modern processors get relatively hot. Even with a common heat sink and fan cooling the processor, operating temperatures may still reach up to 70 °C (160 °F). A thermosiphon can handle heat output at a much wider temperature range than any heat sink and fan, and can maintain the processor 10–20 °C cooler. In some cases a thermosiphon may also be less bulky than a normal heat sink and fan.

Drawbacks

Thermosiphons must be mounted such that vapor rises up and liquid flows down to the boiler with no bends in the tubing for liquid to pool. Also, the thermosiphon’s fan that cools the gas needs cool air to operate.

Engine cooling

1937 diagram of engine cooling entirely by thermosiphon circulation

Early cars and motor vehicles used thermosiphon circulation to move cooling water between their cylinder block and radiator. As engine power increased, increased flow was required and so engine-driven pumps were added to assist circulation. More compact engines then used smaller radiators and required more convoluted flow patterns, so the circulation became entirely dependent on the pump and might even be reversed against the natural circulation. An engine cooled only by thermosiphon is also very sensitive to low coolant level, i.e., losing only a small amount of coolant stops the circulation; a pump driven system is much more robust and can typically handle a lower coolant level.

See also

References

  1. ^ "Thermosyphon technology for Artificial Ground Freezing (AGF)". simmakers.com. 
  2. ^ Holubec, I. (2008). "Flat Loop Thermosyphon Foundations in Warm Permafrost (Prepared for Government of the NT Asset Management Division Public Works and Services and Climate Change Vulnerability Assessment Canadian Council of Professional Engineers" (PDF). 
  3. ^ btfsolar.com
  4. ^ "Thermosiphon Heat Exchangers". apogee.net. 
  5. ^ "What is a Heat Pipe? - Other Topics - Articles - Chemical Engineering - Frontpage - Cheresources.com". Cheresources.com Community. 
  6. ^ Brian Norton (2011) Solar Water Heaters: A Review of Systems Research and Design Innovation, Green. 1, 189–207, ISSN (Online) 1869-8778
  7. ^ Kuemel, Bernhard. "CPU Vapor Cooling Thermosyphon". http://www.overclockers.com/. Retrieved 26 August 2012. 

External links

  • Definition of thermosiphon
  • Another definition of thermosiphon
  • HP Labs report on thermosiphons for computer cooling (PDF)
  • Antique thermosyphon engine cooling
This article was sourced from Creative Commons Attribution-ShareAlike License; additional terms may apply. World Heritage Encyclopedia content is assembled from numerous content providers, Open Access Publishing, and in compliance with The Fair Access to Science and Technology Research Act (FASTR), Wikimedia Foundation, Inc., Public Library of Science, The Encyclopedia of Life, Open Book Publishers (OBP), PubMed, U.S. National Library of Medicine, National Center for Biotechnology Information, U.S. National Library of Medicine, National Institutes of Health (NIH), U.S. Department of Health & Human Services, and USA.gov, which sources content from all federal, state, local, tribal, and territorial government publication portals (.gov, .mil, .edu). Funding for USA.gov and content contributors is made possible from the U.S. Congress, E-Government Act of 2002.
 
Crowd sourced content that is contributed to World Heritage Encyclopedia is peer reviewed and edited by our editorial staff to ensure quality scholarly research articles.
 
By using this site, you agree to the Terms of Use and Privacy Policy. World Heritage Encyclopedia™ is a registered trademark of the World Public Library Association, a non-profit organization.
 



Copyright © World Library Foundation. All rights reserved. eBooks from World Library are sponsored by the World Library Foundation,
a 501c(4) Member's Support Non-Profit Organization, and is NOT affiliated with any governmental agency or department.